Orthopaedic Biomechanics Equipment
Researchers in the Metzger Laboratory design and perform experimental simulations to analyze human movement and joint mechanics with the goal of understanding how injury, repair and reconstruction affect joint kinematics and kinetics. Since the Metzger Lab's inception in 2009, our capabilities have expanded to analyze nearly every joint system in the body, including the spine, knee, shoulder, elbow, hand and foot and ankle, which allows us to collaborate with many industrial and clinical partners. The lab serves as one of the primary resources for orthopaedic surgeons to explore improvements that can help an active and aging population maintain ordinary movements and live pain free through enhanced orthopaedic treatments.
Orthopaedic Biomechanics Equipment List
Properly characterize biomaterials, verify biomechanical components and simulate biological forces and displacements.
Force Capacity:
- 25 kN
- 250 Nm
Add-ons:
- ATI Omega 160 Load Cell
- +/- 3750 N / 240 Nm | Res. 0.25 N / 0.025 Nm
- Spine Kinematics System
Built with the superior accuracy and reliability of the renowned Optotrak 3020 series, Optotrak Certus is the gold standard among research scientists.
- Accuracy: 0.1 mm
- Resolution: 0.01 mm
- Max Freq: 4600 / (n+1) Hz
- Max Markers: 512
The versatile I-Scan tactile pressure mapping system is tailor-made by choosing from over 200 pressure sensors to meet your specific application requirements.
F-Scan:
- 3.9 sensels / cm2
- 0-75 psi range
I-Scan:
- 62.0 sensels / cm2
- 0-250 psi range
The LX-60 Specimen Radiography System is ideal for imaging larger animals and more dense specimens, due to its cabinet size and energy range of up to 60 kV.
Specifications:
- Energy range: 10-60 kV
- Focal spot size, nominal: < 20 µm
- Active Imaging Area: 12 cm x 12 cm
- Resolution: 10 lp/mm contact mode
Scale prototyping and production as your business grows with the Form 3, an affordable, industrial-quality 3D printer that consistently delivers.
- Resolution: 0.001 in
- Laser Power: 250 mW
- Layer Thickness: 0.001-0.012 in
- Build Volume: 5.7 x 5.7 x 7.3 in
Xsens tailored both hardware and software of the Xsens MVN systems to ensure real-time, reliable and accurate human motion analysis.
- Full Magnetic immunity
- Instant 3D Kinematics
- Latency: 30 ms
- Output Rate: 60 Hz
- Wireless Range (Indoor/ Outdoor): 60 ft / 150 ft
- RMS Error: <5 degrees